| Feature | 
            Specification | 
        
        
            | Principle of operation | 
            Laser diode optical detection of actual particulates | 
        
        
            | Dimensions | 
            H 530mm x W 210mm x D 410mm | 
        
        
            | Weight | 
            Approx 18kg | 
        
        
            | Operating temperature and humidity | 
             +5ºC to +60ºC (-41ºF to +140ºF) 
            20-85% RH (tested at 30ºC (86ºF), non-condensing) | 
        
        
            | Storage temperature and humidity | 
             -40ºC to +90ºC (-40ºF to +194ºF) 
            10-90% RH (tested at 30ºC (86ºF), non-condensing) | 
        
        
            | Moisture sensor calibration | 
            ±5% RH (over a compensated temperature range of +10ºC to +80ºC (+50ºF to +176ºF) | 
        
        
            | Moisture sensor stability | 
            ±2% RH typical at 50% RH in one year | 
        
        
            | International codes | 
            ISO 7 to 21, NAS 0 to 12, AS 0 to 12 | 
        
        
            | Contamination standards | 
            Refer to Parker ‘Guide to Contamination Standards’ (DD0000015) on CD 
            MTD : ISO 4406:1999; NAS 1638; AS4059E (Differential); AS4509E (Cumulative) 
            ACFTD : ISO 4406:1987; ISO4406:1991; NAS 1638; AS4509E (Differential); 
            AS4509E (Cumulative); GOST 17216 : 2001 | 
        
        
            | Channel sizes | 
            
            
                
                    
                        | Channel Sizes: MTD μm(c) | 
                     
                    
                        | ISO 4406:1999 | 
                        NAS 1638 | 
                        AS4059E (cum) | 
                        AS4059E (diff) | 
                        MTD 8 Channel | 
                     
                    
                        | >4 μm (c) | 
                        4-6 μm (c) | 
                        <4 μm (c) | 
                        4-6 μm (c) | 
                        >4 μm (c) | 
                     
                    
                        | >6 μm (c) | 
                        6-14 μm (c) | 
                        <6 μm (c) | 
                        6-14 μm (c) | 
                        >6 μm (c) | 
                     
                    
                        | >14 μm (c) | 
                        14-21 μm (c) | 
                        <14 μm (c) | 
                        14-21 μm (c) | 
                        >14 μm (c) | 
                     
                    
                        | >21 μm (c) | 
                        21-38 μm (c) | 
                        <21 μm (c) | 
                        21-38 μm (c) | 
                        >21 μm (c) | 
                     
                    
                        | >38 μm (c) | 
                        38-70 μm (c) | 
                        <38 μm (c) | 
                        38-70 μm (c) | 
                        >25 μm (c) | 
                     
                    
                        | >70 μm (c) | 
                        >70 μm (c) | 
                        <70 μm (c) | 
                        >70 μm (c) | 
                        >30 μm (c) | 
                     
                    
                        | - | 
                        - | 
                        - | 
                        - | 
                        >38 μm (c) | 
                     
                    
                        | - | 
                        - | 
                        - | 
                        - | 
                        >70 μm (c) | 
                     
                    
                        | Channel Sizes: ACFTD μm | 
                     
                    
                        | ISO 4406:1999 | 
                        NAS 1638 | 
                        AS4059E (cum) | 
                        AS4059E (diff) | 
                        GOST 17216:2001 | 
                     
                    
                        | >2 μm | 
                        2-5 μm | 
                        - | 
                        - | 
                        >2-5 μm | 
                     
                    
                        | >5 μm | 
                        5-15 μm | 
                        <5 μm | 
                        5-15 μm | 
                        >5-10 μm | 
                     
                    
                        | >15 μm | 
                        15-25 μm | 
                        <15 μm | 
                        15-25 μm | 
                        >10-25 μm | 
                     
                    
                        | >25 μm | 
                        25-50 μm | 
                        <25 μm | 
                        25-50 μm | 
                        >25-50 μm | 
                     
                    
                        | >50 μm | 
                        50-100 μm | 
                        <50 μm | 
                        50-100 μm | 
                        >50-100 μm | 
                     
                    
                        | >100 μm | 
                        >100 μm | 
                        <100 μm | 
                        >100 μm | 
                        >100-200 μm | 
                     
                
             
             | 
        
        
            | Calibration | 
            MTD : via a certified primary ISO 11171 automatic particle detector using ISO 11943 principles, with particle distribution reporting to ISO 4406:1996 
            ACFTD : fully traceable to gravimetric first principles | 
        
        
            | Recalibration | 
            Contact Parker Hannifin for advice | 
        
        
            | Fluid compatibility | 
            Mineral-based oils and petroleum-based fuel - Contact Parker Hannifin for advice | 
        
        
            | Fluid management | 
            Selectable on screen between 25ml to 100ml | 
        
        
            | Viscosity range | 
            1 to 300cSt | 
        
        
            | Working pressure | 
            3 bar maximum input pressure, if used on-line. Contact Parker Hannifin for further advice | 
        
        
            | Flow range through icountBSplus | 
            Test: 60ml/min | 
        
        
            | Connection interface (On Line) | 
            INLET: 6mm push-fit, DRAIN: 4mm push-fit | 
        
        
            | Fluid operating temperature (Oil) | 
            +5ºC to +70ºC (-41ºF to 176ºF) | 
        
        
            | Fluid operating temperature (Fuel) | 
            +20ºC to +70ºC (-4ºF to 158ºF) | 
        
        
            | Sample bottle size | 
            See Parker ACC Spares list. Contact Parker Hannifin for advice | 
        
        
            | Flush sample size | 
            Selectable option within the icountBS Software: 25ml to 100ml | 
        
        
            | Memory storage | 
            500 tests (Integrated Warning Level) | 
        
        
            | Printer | 
            Thermal dot line printer - see ACC spares list for replacement paper | 
        
        
            | Battery type | 
            Polymer Lithium Ion Battery pack (ACC6NW032) | 
        
        
            | Power requirements | 
            Intergrated supply into the icountBSplus unit | 
        
        
            | Certification | 
            CE Certified. Supplied with EC Declaration of Conformity Certificate |