        - Ranges:
        
            - O2: 0 to 21%
 
            - CO: 0 to 2000 PPM (4000 PPM Max for 15 minutes)
 
            - CO2: 0 to 30%
 
            - Temperature (Flue and net): 32 to 1112°F (0 to 600°C)
 
            - Efficiency: 0 to 99.9%
 
            - Excess Air: 0 to 250%
 
         
         
        - Accuracy:
        
            - O2: ±0.2%
 
            - CO: ±10 PPM < 100 PPM else ±5% of reading
 
            - CO2: ±0.3% reading
 
            - Temperature (Flue and net): ±2°C ±0.3% reading
 
            - Efficiency: ±1% reading
 
            - Excess Air: ±0.2%.
 
         
         
        - Resolution:
        
            - O2: 0.1%
 
            - CO: 1 PPM
 
            - CO2: 0.1%
 
            - Temperature (Flue and net): 0.1°F/C
 
            - Efficiency: 0.1%
 
            - Excess Air: 0.1%.
 
         
         
        - Pre-Programmed Fuels: Natural Gas, Light Oil, Propane, Butane, LPG, and Wood Pellets.
 
        - 11.8" (300 mm) x 0.25" (6 mm) probe with 7.8" (200 mm) stainless steel shaft.
 
        - 10-foot hose
 
        - CE approved
 
     
     
    
 
 
  
                             |