- Compact and lightweight.
- Vibration acceleraton measurement in VIBRATION MODE and shock acceleration
measurement in SHOCK MODE are available.
- Easy reading of 0 to 2000m/s2 without changing sensitivity.
- Charge amplifier assures stable sensitivity.
- Built-in low pass filter cuts unnecessary high-frequency waves.
COMPOSITIONS
Digital Accelerometer Model 1340A Output cable(1m)
Piezoelectric Pickup Model 2304A Dry cell(6LR61)
(with M6 screws,contact pin,handler) Small-size slotted screwdriver
Low noise cable LNC-1A-3(3m) Shoulder case
Magnet holder MG-1 Operation Manual
Thông số kỹ thuật
    
        
            | 
             INPUT TRANSDUCER 
             | 
            
             Piezoelectric pickup Model 2304A Approx.50pC/m/s2 
             | 
        
        
            | 
             INPUT TERMINAL 
             | 
            
             Charge input type,BNC connector 
             | 
        
        
            | 
             MEASURING RANGE 
             | 
            
             1-1,999m/s2 
            (Option:0.1-19,990m/s2(Peak)) 
             | 
        
        
            | 
             RESOLUTION 
             | 
            
             1m/s2(Peak) (Option:10m/s2 
             | 
        
        
            | 
             FREQUENCY RANGE 
             | 
            
             500Hz-5KHz,Within 5% 
             | 
        
        
            | 
             LOW-PASS FILTER 
             | 
            
             Cut-off frequency 500Hz(-3dB),-12dB/OCT 
             | 
        
        
            | 
             ACCURACY 
             | 
            
             3% of reading,±1m/s2 
            (80Hz sine wave,100m/s2 vibration,23°C±3°C) 
             | 
        
        
            | 
             DETECTION METHOD 
             | 
            
             VIBRATION Detection of absolute value of sine wave 
            calibration, 
            peak value indication. 
            SHOCK Detection of mean value,peak hold. 
             Releasable by reset button. 
            Peak hold is effective for acceleration of 10m/s2 
            (For optional specifications,peak hold is effective for 100m/s2 
             | 
        
        
            | 
             RESET FUNCTION 
             | 
            
             For use in SHOCK MODE to clear held value. 
             | 
        
        
            | 
             AC OUTPUT 
             | 
            
             100mv/(m/s2),±2V,output resistance 1KΩ,mini-plug. 
            (Option:10mv/(m/s2) 
             | 
        
        
            | 
             DIGITAL INDICATOR 
             | 
            
             LCD,3(1/2)digits 
            Sample rate VIBRATION About 3 times/sec. 
             | 
        
        
            | 
             POWER SUPPLY 
             | 
            
             9V alkaline dry cell (6LR61)×1 Continuous use for more than 50 
            houres 
            (Or 9V manganese cell (006P) ×1) 
             Bettery alarm about 7V or less,current consumption about 5mA. 
             | 
        
        
            | 
             TEMPERATURE STABILITY 
             | 
            
             -10°C-50°C 
             | 
        
        
            | 
             WEIGHT 
             | 
            
             Body Approx. 220g 
             Full set with accessory Approx. 800g 
             | 
        
    
Xem thêm: 
Thiết bị đo độ rung 1422A Showa