Specifications
 
 
    
    
        
            | Name | 
            High precision dispenser with revision function | 
         
        
            | Model | 
            S-SIGMA-X3-V5 | 
            S-SIGMA-X3-V2 | 
         
        
            | Dispensing method | 
            Air pulse | 
         
        
            | Discharge pressure setting | 
            Microcomputer control electro/ pneumatic method | 
         
        
            | Dispense mode | 
            Timed mode / manual mode | 
         
        
            | Discharge pressure setting range | 
            0.010-0.500 MPa | 
            0.005-0.200 MPa | 
         
        
            | Discharge time setting range | 
            0.001 ... 9999.999s | 
         
        
            | Vacuum pressure set range | 
            -0.020-0 MPa | 
            -0.010-0 MPa | 
         
        
            | Main function | 
            Water head difference automatic compensation, dripping automatic prevention, automatic residual quantity warning, α revision, δ revision, 
            Vacuum pressure revision, residual quantity indication revision, dispense counter, stopwatch, 
            Japanese-English indication reshuffling, exhaust error, pressure change error, pressure over error, 
            Vacuum pressure error, solenoid valve error, solenoid valve warning | 
         
        
            | The number of the channels | 
            100 CH | 
         
        
            | RS-232C serial communication | 
            Possibility | 
         
        
            | Input signal | 
            We pre-set dispense, channel reshuffling, dispense mode reshuffling, channel, 
            Channel designation, channel step | 
         
        
            | Output signal | 
            While is completed, and dispense cycles among dispense lady, dispense; pressure change error, 
            Under solenoid valve alarm, error, residual quantity warning, electricity | 
         
        
            | Rating power supply and frequency | 
            AC100-240 V 50/60 Hz | 
         
        
            | Power Consumption | 
            30W | 
         
        
            | Conformity standard | 
            CE marking (low voltage order, EMC order) 
            EU RoHS | 
         
        
            | Exterior dimensions W*D*H | 
            W300 X D250 X H100 mm | 
         
        
            | Weight | 
            5.4 kg | 
         
    
 
Note: When you use syringe, cartridge more than 70 ml, please talk to us. 
  
                             |