| ITEM/ MODEL | 
            LC-200R | 
            LC-200RB | 
        
        
            Measurement Principle  
            & Method | 
            Direct Loading Method with Load-Cell Feedback/ Direct Linear Displacement Measurement | 
        
        
            | Standars Conformed | 
            ISO 6506-2/ ISO 6508-2/ ASTM E 18/ ASTM E 10/ ASTM E 140/ ASTM D 785 
            JIS B 7726/ JIS K 7202/ JIS Z 2245/ | 
        
        
            Display & Operation Panel 
             | 
            8- Color LCD Touch Panel Display | 
        
        
            | Available Languages | 
            Japanese/ English/ German/ French/ Italian/ Spanish/ Chinese/ Korean | 
        
        
            Loading Principle 
            & 
            Measurement Operation | 
            Fully-Automatic Load Control Method: 
            Fully-Automatic Measurement Operation; Descent of Load Shaft ~ Minor Load Application ~ 
            Test Load Application- Hold- Release- ~ Hardness Display ~ Ascent of Load Shaf 
            ※ Only Manual Operation: Elevation of Specimen Surface within 0.5 ~ 8 mm to Indenter | 
        
        
            | Load    | 
            Minor Load | 
            N:29.42 98.07 | 
        
        
            | kgf : 3 10 | 
        
        
            Test Load 
             | 
            N:147.1   294.2     441.3   588.4   980.7     1471 | 
        
        
            | kgf : 15   30     45       60     100     150 | 
        
        
            | Special Load for Brinelll Test Conforming to ISO 6506-2 | 
            – | 
            N: 61.29, 76.61, 98.07, 153.2, 196.1, 245.2, 294.2 
            306.5, 392.3, 612.9, 980.7, 1177, 1226, 1839 | 
        
        
            | – | 
            kgf: 6.25, 7.8125, 10, 15.625, 20, 25, 30, 
            31.25, 40, 62.5, 100, 120, 125, 187.5 | 
        
        
            | Flexible Special Rockwell Load Setting | 
            Available Special Customized Rockwell Type Test by Setting Minor Load/ Test Load Combination 
            between 29.42 N (3 kgf) and 1961 N (200 kgf) | 
        
        
            | Maxmum Travel of Load Shaft  | 
            Max. 8 mm | 
        
        
            | Test Load Dwell Time | 
            0 ~ 999 s (Key Entry in unit of 1 s/ Factory Setting : 3 s) | 
        
        
            Measurement Speed 
             | 
            For Normal Measurement: Approx. 13 s/ 1 cycle | 
        
        
            Resolution 
             | 
            Display: 0.01 HR | 
        
        
            | Plastic Measurement Mode | 
            Available Load Control Method Conforming to JIS Z 7202 and ASTM D 785 | 
        
        
            | Hardness Conversion | 
            Conversion & Display in compliance with ASTM E 140 | 
        
        
            OK/ NG Criteria 
            & Limit Setting | 
            Upper and Lower Limit Setting between 0.01 ~ 130 HR and OK/ NG Display | 
        
        
            | Self Diagnosis | 
            Display Troubles with Motors and Switches | 
        
        
            | HR Scale Display | 
            C, D, A, G, GW, B, BW, F, FW, K, KW, E, EW, H, HW, P, PW, M, MW,L,LW,V, VW, S, SW, R, RW, 
            15N, 30N, 45N, 15T, 15TW, 30T, 30TW, 45T, 45TW, 15W, 15WW, 30W, 30WW, 45W, 45WW, 
            15X, 15XW, 30X, 45XW, 15Y, 15YW, 30Y, 30YW, 45Y, 45YW | 
        
        
            | Brinell Test Mode | 
             – | 
            Display HB Hardness based on Depth of Indentation 
            ※ Reference only to ASTM E 10 | 
        
        
            | Test Load Display | 
            Display Test Load in kgf and SI simultaneously on SCALE SELECTION Screen | 
        
        
            | HR Data Correction | 
            Max. Five Points each on 3 HR Scales/ Offset on each HR/ HR on Convex Cylindrical Surfaces (In compli-ance with ASTM E 18 and JIS Z 2245)/ HRC on Convex Round Surfaces (In compliance with JIS Z 2245) | 
        
        
            | HR Data Editing | 
            Data Ediing/ Statistic Data(Test Times/ Max./ Min./ Mean/ Range/ Standard Deviation/ Dispersion/ 
            Coefficient of Variation)/ Graph Chart Display/ Histogram Display | 
        
        
            | MAX. Indentation Depth | 
            Detection and Output of Max. Indentation Depth | 
        
        
            Special Test Mode For Detection On Process Of  
            Displacement of Load  
            & Indentation Depth | 
              | 
            Detection of Displacement of Test Load &IndentationDepth on Procese of Loading and output to outerPC by RS232C in reai-time | 
        
        
            Data Output & 
            Communicaiotn Signal | 
            RS232C : 2 Channels (For Printer & PC) / OPTION : P.I.O.(For External Control) | 
        
        
            | Data Printout Mode | 
            a. HR Value/ b. HR Value & Conversion Data/ c. HR Value & Max.Depth of Indentation/ d. HR Value &OK-NG Criteria/ e. HR Value & Statistic Data/ f. HR Value, Mean Value & OK-NG Criteria/. ConversionData/ h. Conversion Data & OK-NG Criteria/ i. Conversion Data& Statistic Data/ j. Conversion Data, Mean Value & OK-NG Criteria/ k. Max.Depth of Indentation | 
        
        
            | Illumination Light | 
            White LED Spot Illumination | 
        
        
            | Specimen Fixing Adapter | 
            Available as Option:2 Types / Large & Small | 
        
        
            | Max. Height of Specimen | 
            255 mm(10″) | 
        
        
            | Max.Depth of Specimen | 
            170 mm(6.7″) | 
        
        
            | Demension | 
            (W)220×(D)465×(H)810 mm | 
        
        
            | Weight | 
            Approx. 100 kg(Including Standard Accessories) | 
        
        
            | Power Supply | 
            AC100 ~ 240 V 50/60 Hz/ Single Phase (Switchable in outside) |