| General Specifications | 
        
        
            | Infrared Imaging | 
            IR Resolution | 
            512 × 384 pixels | 
        
        
            | Field of View (FOV) | 
            23°× 17° | 
        
        
            | Temperature Range | 
            -20℃~﹢650℃ (-4℉ ~ 1202℉) | 
        
        
            | Minimum Focus Length | 
            0.1m (Standard Lens) | 
        
        
            | Spatial Resolution (IFOV) | 
            0.78mrad | 
        
        
            | Thermal Sensitivity (NETD) | 
            ≤0.05℃@30℃ | 
        
        
            | Measurement Accuracya | 
            ±2℃ or ±2% whichever is greater @ Environment Temperature 10℃~35℃ | 
        
        
            | Focus | 
            Manual | 
        
        
            | Spectral Range | 
            8 to 14 μm | 
        
        
            | Detector Type | 
            Focal Plane Array (FPA) uncooled microbolometer | 
        
        
            | Zoom | 
            10X continuous digital zoom | 
        
        
            | Palettes | 
            15 palette options (iron, glowbow, red-hot, white-hot, yellow) | 
        
        
            | Image Processing | 
            Palette Switching | 
            Tap palette icon | 
        
        
            | Noise Calibration | 
            Automatic noise calibration FFC / manual noise calibration FFC | 
        
        
            | Correction Settings | 
            Emissivity, reflected background temperature, relative humidity, ambient temperature, measuring distance, transmission | 
        
        
            | Emissivity Adjustment | 
            0.1 to 1.0 | 
        
        
            | Regional Emissivity Adjustment | 
            Support | 
        
        
            | Measurement & Analysis | 
            Automatic Capture of High, Low and Average Temperature | 
            Support | 
        
        
            | Isotherm | 
            Above / Below | 
        
        
            | ROI Measurement Modes | 
            8 moveable spots 
            8 moveable area boxes (min/max) 
            1 lines (min/max) 
            Emissivity set for each ROI | 
        
        
            | Temperature Alarm | 
            User-defined temperature threshold, audible and visual alarm of above/below temperature | 
        
        
            | Image Format | 
            Standard JPEG, including raw temperature data |