            | Bridge power supply | AC2.0 Vrms sine wave 5 kHz±0.1 kHz | 
        
            | Applicable transducer | Strain gage based torque transducer | 
        
            | Input range | 0.5 mV/V ~ 3 mV/V (1 mV/V = 2 000 μst) | 
        
            | Output | ±10 V output (±0.5 mV/V input, at bridge power supply AC2.0 Vrms)
 | 
        
            | Output Load Resistance | Resistance load 2 kΩ or more Output capacitance load 0.1 uF or less
 | 
        
            | Zero adjustment range | ±2.5 mV/V Coarse adjustment Automatic balance
 Fine adjustment Zero adjustment trimmer
 Resistance section Approx.1 %(±2.5 mV/V)
 Capacitance section Up to 2 000 pF is possible
 Automatic balancing time Approx.1 s,
 Accuracy ±0.2 %F.S.,
 Back-up time : 24 h or more
 | 
        
            | Non-linearity | 0.05 %F.S. | 
        
            | Temperature efficient | Zero point ±0.1 μV/℃ (Input conversion) Sensitivity within ±0.05 %F.S./℃
 | 
        
            | CALIB | Set by digital switch Setting range : 0 ~ ±9 999 μst., Accuracy : ±0.5 %
 | 
        
            | Frequency response range | DC ~ 2 kHz (Filter : W/B) (Changeable to 1 Hz, 10 Hz, 100 Hz, 300 Hz, 1 kHz or W/B)
 10 Hz ~ W/B:+1 dB -3 dB±1 dB,
 1 Hz:+1 dB -3 dB±3 dB
 | 
        
            | Display section | Output voltage display 0 ~ ±10.000 Digital display (Green LED)
 Sampling rate: Approx. 4 times/s
 | 
        
            | ERROR function | (+10 V or more or -10 V or less), the display flashes 0.000 or -0.000 on and off and also ERROR will be shown. (Photocoupler output) | 
        
            | Remote function | Automatic balance ±CALIB | 
        
            | LOCK function | Automatic balance Prohibit the operation of ± CALIB
 (Including ±CALIB of automatic balance for remote function)
 | 
        
            | Operating temp./humidity range | Temperature -10 ℃ ~ 50 ℃ Humidity 85 %RH or less (Non condensing)
 | 
        
            | Power supply | Power supply voltage AC100 V±10 V 50/60 Hz Power consumption Approx. 10 VA (at AC100 V)
 | 
        
            | Outline dimensions (W x H x D)
 | 42 mm x 176 mm x 284.4 mm (Excludes protruding parts.) | 
        
            | Weight | Approx. 1.5 kg |