            | Bridge power supply | DC10 V±0.3 V within 30 mA (Changeable to DC5 V or DC2.5 V)
 | 
        
            | Input range | 0.5 mV/V ~ 3 mV/V | 
        
            | Sensitivity adjustable range | 1 000 times, 2 000 times or 3 000 times (Changeover with the internal dip switch)
 Adjust 1/1 ~ 1/4 against each setting.
 | 
        
            | Output | DC±10 V (Not isolated) | 
        
            | Output Load Resistance | 2 k-ohm or more | 
        
            | Zero adjustment range | ±0.25 mV/V *Tare weight cancellation will be adjusted by installing resistance externally. | 
        
            | Non-linearity | within 0.02 %F.S. | 
        
            | Temperature efficient | Zero point ±1 μV/℃ (Input conversion), Sensitibity within ±0.01 %F.S/℃
 | 
        
            | Frequency response range | 1 Hz, 10 Hz, 100 Hz, 1 kHz (Changeable by internal DIP switch) | 
        
            | CALIB | 1 mV/V±0.002 mV/V (Changeable to either 0.5 mV/V±0.001 mV/V or 0.25 mV/V±0.000 5mV/V if specified at the order.) | 
        
            | Operating temp./humidity range | Temperature -10 ℃ ~ 50 ℃, Humidity 85%RH or less (Non condensing)
 | 
        
            | Power supply | Power supply voltage AC100 V (AC90 V ~ 115 V), 50/60 Hz, Power consumption Approx. 5 VA (at AC100 V)
 | 
        
            | Outline dimensions (W x H x D)
 | CSA-507C 44 mm x 90 mm x 110 mm CSA-507C-99 44 mm x 90 mm x 230 mm
 (Excludes protruding parts)
 | 
        
            | Weight | CSA-507C Approx. 700 g CSA-507C-99 Approx. 1 200 g
 |