| Power supply voltage to sensor |
Load Cell 12 VDC±1.2 VDC / within 40 mA/unit
Angle detector 12 VDC±1.2 VDC / within 20 mA |
| Applicable transducer |
Load Cell Strain gage transducers(350Ω)3 points(load cell 1 to 3)
Angle detector WR-7UHA112-V-1(MIDORI PRECISIONS) |
| Input range |
Load cell F.S. setting can be made at the input from 0.5 mV/V to 3 mV/V
Angle detector 1.40 V to 5.32 V |
| Display of moment ratio |
Display range from 60 % to 125 % (Bar graph LED)
Minimum resolution 2.5 % |
| Present load display |
Display range from -99 t to 999 t or from -9.9 t to 199.9 t |
| Present working radius |
Display range from 0.0 m to 99.9 m |
| Condition display |
Applied load cell is specified. (Load cell No.1 to 3) |
| Monitor display |
One of the selection has been displayed either of Limit load, Limit radius, Jib angle, Moment No., Jib No. or Range No. |
| Limited output monitor display |
Display output condition of limited output No.1 to No.6 |
| Display of 90 % and 100 % |
Display signal output condition of 90 % and 100 % of the lifting load |
| Display of up and down |
Display input signal condtion for correction executing instruction of lift-up and lift-down |
| Display times |
Changeable to 1 times/s, 2 times/s or 0.5 times/s |
| Buzer for emergency |
EB2112(Panasonic Corporation) or DSEB2112(Devices Sales Technology Co.,Ltd.) |
| Power supply voltage |
24 VDC (18 VDC to 36 VDC), Power consumption Approx. 3 A |
| Outline dimensions (W×H×D) |
100 mm x 210 mm x 162.9 mm (Excluding protruding parts) |
| Weight |
Approx. 2.1 kg |