            | Bridge power supply | DC10 V±0.3 V within 120 mA (Changeable to DC2.5 V or 5 V) with remote sensing.
 | 
        
            | Input range | F.S. setting can be made with the input range from 0.3 mV/V to 3 mV/V. (At the time of bridge power supply is DC10 V.)
 ±F.S. setting can be available with the input range from ±0.6 mV/V to ±3 mV/V.
 (At the time of selection of of +/- display mode at the function setting)
 (At the time of bridge Power Supply is DC10 V)
 | 
        
            | Zero adjustment range | ±2.4 mV/V | 
        
            | Non-linearity | 0.01 %F.S. | 
        
            | Temperature efficient | Zero point ±0.2 μV/℃ (Input conversion) Sensitivity ±0.001 5 %F.S./℃
 | 
        
            | A/D sampling | 100 times/s | 
        
            | Input filter | 4 Hz | 
        
            | Load display |  | 
        
            | Display range | -1 000 ~ 11 000 (Changeable to x 2, x 5 or x 10) -11 000 ~ 11 000 (Changeable to x 2, x 5 or x 10,
 When +/- display mode is set with Function setting.)
 | 
        
            | Condition display | RUN, A/Z, LOCK, HOLD, CHECK | 
        
            | Display of setting | 7segment fluorescence display tube and each 7 digits of S1, S2, S3 and S4 with 4.5 mm character height. | 
        
            | Bar meter display | Displays the percentage of present load compared to the rated capacity (100 %) by 11 dots bar meter display. | 
        
            | Display times | 4 times/s (20 times/s can be available depending on the setting.)
 | 
        
            | External control function | ZERO, A/Z, A/Z OFF, HOLD, LOCK, A-SEL | 
        
            | Comparator function |  | 
        
            | Set value | -999 999 ~ 999 999 | 
        
            | Set quantity | S1, S2, S3, S4 points | 
        
            | Conversion times of comparator | 30 times/s | 
        
            | Contact output function | 4 points of S1, S2, S3 and S4 | 
        
            | Operating temp./humidity range | Temperature -10 ℃ ~ 50 ℃, Humidity 85 %RHo r less (Non condensing) | 
        
            | Power supply voltage | AC100 V (AC85 V ~ AC132 V) 50/60 Hz | 
        
            | Power consumption | Approx.19 VA (without options, at AC100 V) Approx.23 VA at maximum (with options.)
 | 
        
            | Outline dimensions(WxHxD) | 192 mm x 96 mm x 175 mm (excludes protruding parts) | 
        
            | Weight | Approx. 1.9 kg (without options) |