- Technical Specifications
| Parameter |
Value |
| Overall Rated voltage AC, V |
380 ± 38 |
| Frequency, Hz |
50 ± 1 |
| Most output voltage (rms), kV |
15
|
| Maximum voltage burning, kV |
15 |
| Short-circuit current to burn, A |
20
|
| Maximum output power, min, kVA |
225
|
Maximum loading capacity, uF (at 7.5 kV)
|
6 |
| Q-factor, min |
15 |
| Lifting speed of the test voltage, max kV/s (the speed set in the configuration) |
1 |
| Operating current on the high side, A |
15 |
| Current consumed on the low side, max, A |
80 |
Reduced error meas. voltage, maximum, %
|
3 |
| Continuous operation at maximum power, min |
20
|
| Consumptionpower, not more, kVA |
30 |
| Dimensions L × W × H, mm |
2540×1130×2030 |
| Weight, kg |
2215 |
- Operating Conditions
The device is designed for an indoors operation under the following conditions:
| Condition |
Value |
| Air temperature, °С |
from +1 to +35
|
Relative humidity, %, up to
|
80 at +25 °С |
Atmospheric pressure, kPa (mm hg)
|
84,0 – 106,7 (630 – 800) |
-
|