- Continuous gas sampling of SF6 - SO2 - HF - H2O 
- High precision infra-red gas detector for SF6 purity over the range 0-100% 
- Electrochemical SO2 sensor for trace analysis of contamination gas 0-100ppm or 0-500ppm 
- Electrochemical HF sensor for trace analysis of contamination gas 0-10ppm 
- High speed dew-point sensor for moisture analysis -65°C to + 20°Cdp (or ppmv) 
- Input pressure 0.5 to 10 bar with safety blow off valve 
- Gas flow rate 0.1 - 1 litre per minute controlled by flow gauge 
- Programmable alarms with outputs and visual warning 
- RS232 / RS485, 0-5V and 4-20mA current loop outputs (all user programmable) 
- On board data-logger with 2048 sample points 
- Windows data logging software with MS-Excel compatible graphing 
- Supplied with a 2m armored sampling hose with DILO compatible fittings 
- Full sample kit available (sample hoses, DILO couplings, printer, Peli-case) 
- SF6 gas recovery bag available 
- Compatible with DILO style gas recovery systems 
 
 
Thông số kỹ thuật 
 
 
    
        
            | 
             Technical Data: Analyzer 
             | 
         
        
         
        
            | 
             Voltage 
             | 
            
             90-260Vac, 50/60Hz 
             | 
         
        
            | 
             Analyzer dimensions 
             | 
            
             350mm x 263mm x 150mm 
             | 
         
        
            | 
             Weight 
             | 
            
             7 kg 
             | 
         
        
            | 
             Display 
             | 
            
             20 x 4 characters (9mm) back lit LCD. Displays SF6-H2O-HF-SO2, pressure, temperature, date & time 
             | 
         
        
            | 
             Warm up time 
             | 
            
             3-4 minutes at 20°C 
             | 
         
        
            | 
             Operating temperature 
             | 
            
             -10°C to 40°C 
             | 
         
        
            | 
             Max inlet pressure 
             | 
            
             10 bar (protected) 
             | 
         
        
            | 
             Voltage outputs 
             | 
            
             0-5V linear, user-programmable 
             | 
         
        
            | 
             Current outputs 
             | 
            
             4-20mA linear, user-programmable 
             | 
         
        
            | 
             Digital outputs 
             | 
            
             RS232 (RS485 option available): data streamed on demand 
             | 
         
        
            | 
             Flow 
             | 
            
             100 to 1000 ml.min-1 
             | 
         
        
            | 
             Data Log 
             | 
            
             On board data logger with 2048 sample points 
             
             
             | 
         
    
 
 
  
                             |