| General indicators | Dimensions / Weight | 1600 mm (L) x 810 mm (W) x 1120 mm (H) 300 kg | 
        
            | Channel size | 500mm (width) × 300mm (high) | 
        
            | Conveyor speed | 0.22m / s | 
        
            | Conveyor height | 675 ± 10mm | 
        
            | Maximum load | 100 kg (evenly distributed) | 
        
            | Silk resolution | 40AWG (classic), 34AWG (applied value) | 
        
            | Penetration | 10 steel (classic), 8m steel (application value) | 
        
            | X-ray generator | Tube voltage | 1 0 0kV | 
        
            | Tube current | 0.4 - 1.2mA (adjustable) | 
        
            | power | 600W | 
        
            | Beam divergence angle | 80 ° | 
        
            | Image processing system | Image enhancement | Black and white, anti-color, high energy penetration, low energy penetration, organic exclusion, inorganic removal, super enhancements, variable absorptivity, pseudo color, etc. | 
        
            | Constituency and magnification | Optional, 1 - 64 times magnified, support continuous zoom | 
        
            | Image back position | 50 images have been checked for playback | 
        
            | Image storage | Save images in real time, and can carry out any image processing, continuous work to save, storage capacity of at least 100000 | 
        
            | Radiation safety | Radiation dose rate | 0.4 μGy  / h (5 cm from the shell), in line with all international and domestic health and safety standards | 
        
            | Single check dose | ≤1.0μGy / h | 
        
            | Film safe | Compliance with ASA / ISO1600 standard film safety | 
        
            | System functions | Date / time display, baggage count, user management, system work timing, ray out timing, power-on self-test, image storage and retrieval, maintenance diagnostics, two-way scanning, image recognition training | 
        
            | Optional function | High-density area alarm, explosives / drug-assisted inspection, dangerous goods image insertion, network expansion | 
        
            | Installation data | Operating temperature / relative humidity | 0 ° C to + 40 ° C / 5 ° C to 95 ° C (no condensation) | 
        
            | Storage temperature / relative humidity | Negative 40 ° C to + 60 ° C / 5 ° C to 95 ° C (no condensation) | 
        
            | power supply | AC power supply 220 volts (-15% to +10%), 50 Hz ± 3 Hz | 
        
            | Power consumption | 1.0 kVA |