| Model | F-S Master K-_N (Please refer to “Models of F-S Master” below.) | 
        
            | Accuracy | Force | +/-0.2% F.S. +/-1 digit | 
        
            | Displacement | +/-0.1mm +/-1 digit (with no load) | 
        
            | Unit of measurement | Force | N,kgf,lbf | 
        
            | Displacement | mm, inch | 
        
            | Range | Load cell | 2N(200gf), 5N(500gf), 10N(1kgf), 20N(2kgf), 50N(5kgf), 100N(10kgf), 200N(20kgf), 500N(50kgf), 1000N(100kgf), 2000N(200kgf), 5000N(500kgf)(Selectable from DPU series) | 
        
            | Test stand | Selectable from 50N(5kgf), 500N(50kgf), 1000N(100kgf), 2500N(250kgf), 5000N(500kgf) | 
        
            | Display | Force | 4-digit LCD(e.g.Resolution of 5N loadcell is 0.001N) | 
        
            | Displacement | 0.01mm(Displayed at F-S Recorder) | 
        
            | Test speed | 0.1mm/min(Displayed at F-S Recorder) | 
        
            | Deflection at maximum force | Please refer to “Model list of F-S Master” below. | 
        
            | Model:Stroke:Speed | MSF-50N | MSL:80mm | 
        
            | MX2-500N | 0.5K2: 240mm :10-300mm / min | 
        
            | MX2-1000N | 1K2: 295mm :10-300mm / min | 
        
            | EMX-1000N | 1KE: 280mm :0.5-600mm / min | 
        
            | MX2-2500N | 2.5K2:310mm :10-300mm / min | 
        
            | MX-5000N | 5K: 350mm :10-300mm / min | 
        
            | *1 Please refer to “Model list of F-S Master” for model detail. *2 ”Stroke” means the maximum length from the top of force gauge to the table of test stand. Therefore, stroke varies depending on the load cell and the attachments combined.
 | 
        
            | Sampling rate | 2000 data / sec. (max) | 
        
            | Display update | 10 times / sec. | 
        
            | Output | USB,Digital(RS232C),Analog(Approx. +/-2V),Various comparator output,Overload output | 
        
            | Function of test stands | Stroke limit, Overload prevention(*1), Force control(*2), Emergency stop *1 We cannot assure the perfect prevention against sensor break-down.
 *2 The value of force control is specified by the absolute value.
 | 
        
            | Power | AC100V-240V Free input(*Power is necessary for both test stand and force analizer respectively. ) | 
        
            | Accessory | Instruction manual, 2 pcs of power cable, 2 pcs of spare hues, Inspection certificate | 
        
            | Driver CD-ROM, Data importing software:FAP Logger, Graph drawing software F-S Recorder |