| INSULATION RESISTANCE |
|
| Test Voltage (DC V) |
250V / 500V / 1000V |
| Output Ranges on Open Circuit |
+10% |
| Measuring Ranges |
250V : 0-100M Ohm / 500V : 0-200M Ohm / 1000V : 0-200M Ohm, 0-2000M Ohm |
| Mid-Scale Vale |
250V : 1M Ohm / 500V : 2M Ohm / 1000V : 4M Ohm |
| Scale Multipliere |
250V : x 1/2 / 500V : x 1 / 1000V : x 2 |
| Accuracy |
+/- 5% of full value |
| Output Short-Circuit Current |
+/- 1.3 mA |
| CONTINUITY |
|
| Measuring Ranges |
3 Ohm / 500 Ohm |
| Output Short-Circuit Current |
>= 250 mA |
| Accuracy |
+/- 1% of scale length |
| AC VOLTAGE |
|
| AC Voltage Range |
0 ~ 600V AC |
| Accuracy |
+/- 3% of scale length |
| GENERAL |
|
| Voltage Warning |
Warning light circuit live lit from 90Vdc/70Vac buzzer beep from 24Vac/dc |
| Battery Check |
Battery check indicate good batteries from 8Vdc to 13Vdc during a load test of 205mA |
| Battery OK |
Battery OK Led from 6.5Vdc and is operative while testing |
| Power Source |
1.5V SUM-3 (AA) x 6 or equivalent |
| Dimension |
205(L) x 90(W) x 55(D)mm |
| Weight |
Approx. 550g (battery included) |
| Accessories |
Test leads, fuse (0.5A 250V), shoulder belt, instruction manual, batteries |