| Voltage Test Type |
AC/DC |
| Voltage Range |
0-2000 AC 0-2800 DC |
| Leakage Current Set Point |
1-20 mA AC 1-5 mA DC |
| Input Voltage Requirements |
117-127 V, 50 /60 Hz |
| Fuse Requirements |
120 V, 2 A Slow Blow |
| Arc Detect |
Independent High Frequency Circuit |
| Leakage Detect |
Independent Low Frequency Circuit |
| Ground Continuity Set Point |
0.08-1.5 Ω, Defeatable |
| Ground Continuity Test Current |
100 mA |
| Test Time Range |
1 - 60 Seconds |
| Ramp Time Range |
1 - 5 Seconds |
| Voltage Meter Accuracy |
± 2 % |
|
HV Shutdown by Ground Fail
|
< 7 mS
|
| Duty Cycle |
100% |
|
Discharge Time
|
< 7 mS VAC
< 1.3 Sec VDC at open circuit
|
| Transformer Power |
< 500 VAC |
| Pass/Fail Repeatability |
± 3 % |
|
Output Connector
|
NEMA plug, Alligator Clip (HT-3000PR only)
|
| Display |
4 digits LED display |
| Test Indicator |
Led indicators |
| Failure Indicator |
Led indicators and buzzer |
| Programable |
No |
| PLC Interface |
Optional |
| TestLink (With GF-30AC) |
Optional |
| Computer Control |
No |
| Voltage Hold on failure |
No |
| Top Mounted Handle |
Optional |
| Test Defeat |
Ground Continuity |
| Autoreset on Pass |
Optional |
| Operation Temperature |
15 - 40 °C |
| Relative Humidity Range |
0 - 90 % Non-condensing |
| Dimensions |
9-1/4" wide x 4-3/4" high x 10" deep |
| Weight |
14 Lbs |
| Calibration |
One year calibration Certificate |
|
Test Cords
|
Return Lead, Power Cord
Ground Continuity Connector Tip
J2 and J3 Optional
Alligator Clip (HT-3000PR Only)
|