| Measuring values | 
            temperature | 
         
        
            | Output voltage | 
            TRV: 1x 0..10 V or 0..5 V, LCD/relay: 0..10 V or 0..5 V (live-zero can be configured via Thermokon USEapp), min. load 5 kΩ | 
         
        
            | Output ampere | 
            TRA: 1x 4..20 mA, max. load 500 Ω | 
         
        
            | Output passive | 
            depending on used sensor | 
         
        
            | Output switch contact | 
            Relay: 2x floating contact NO for 24 V ~ or 24 V = / 3 A, (optional) | 
         
        
            | Network technology | 
            LON FT (free topology), RS485 Modbus | 
         
        
            | Power supply | 
            15..24 V = (±10%) or 24 V ~ (±10%) SELV, TRA: 15..24 V = (±10%) SELV, LCD/relay/BUS: 15..35 V = or 19..29 V ~ SELV | 
         
        
            | Power consumption | 
            TRV: typ. 0,42 W (24 V =) | 0,84 VA (24 V ~), TRA: typ. 0,5 W (24 V =), LON: typ. 0,5 W (24 V =) | 1,7 VA (24 V ~), LCD/relay/BUS: max. 2,5 W (24 V =) | 4,3 VA (24 V ~) | 
         
        
            | Measuring range temp. | 
            -50..+50 | -20..+80 | -15..+35 | -10..+120 | 0..+50 | 0..+100 | 0..+160 | 0..+250 °C, TRV | TRA: adjustable at the transducer, default setting: 0..+100 °C, LON: -45..+130 °C, LCD/relay/RS485 Modbus: can be configured via Thermokon USEapp, default setting: -20..+80 °C, passive: depending on used sensor | 
         
        
            | Accuracy temperature | 
            measuring current typ. <1 mA, ±0,5 K (typ. at 21 °C within default measuring range), LON: ±0,5 K (typ. at 21 °C), passive: ±0,3 K (typ. at 21 °C), depending on used sensor | 
         
        
            | Display | 
            LCD 29x35 mm with RGB backlight | 
         
        
            | Enclosure | 
            enclosure USE-S, LCD/relay/RS485 Modbus: enclosure USE-M, PC, pure white, LCD: cover PC, transparent, LON: PA6, pure white, with quick lock screws | 
         
        
            | Protection | 
            IP65 according to EN 60529 | 
         
        
            | Cable entry | 
            M16 for wire max. Ø=8 mm, LON: M20 for wire max. Ø=8 mm, LON: seal insert for double cable entry for wire max Ø=6 mm, Relay: M20 for wire max. Ø=8 mm incl. seal insert for double cable entry for wire max Ø=6 mm, BUS: M25 with fourfold cable entry for wire with max. Ø=7 mm, removable (all types enclosure USE) | 
         
        
            | Connection electrical | 
            removable plug-in terminal, max. 2,5 mm², LON: terminal block, max. 1,5 mm², BUS terminal: removable plug-in terminal, max. 1,5 mm², passive: 2-wire (default), 3-wire or 4-wire, TRV: 3-wire, TRA: 2-wire | 
         
        
            | Pocket | 
            brass, spring loaded sensor | 
         
        
            | Ambient condition | 
            enclosure: -35..+70 °C, max. 85% rH short term condensation, enclosure passive: -35..+90 °C, max. 85% rH short term condensation | 
         
        
            | Weight | 
            passive: 80 g, TRV/TRA: 120 g | 
         
        
            | Mounting | 
            installation possible in or across the direction of the pipe, LON: Use tightening straps for installation | 
         
        
            | Notes | 
            for other sensors please request | 
         
    
 
  
                             |