Features 
· The linear amplifier type is adopted as the power supply part, and the 
output voltage waveform is a sine wave with little distortion. 
Moreover, it is also possible to cope with high frequencies, so it can be manufactured as an inductive breakdown voltage tester. 
· As for specifications, custom correspondence is possible up to frequency 2 kHz, capacity 10 kVA, output voltage 10 kV.
 Output waveform (2.3 kV, 50 Hz) Ramp up / down waveform (up 3 sec / test 2 sec / down 3 sec) 
 
Production example
    
        
            |  General specification | 
        
        
            | Type name | 
            TS-EA 0051 | 
        
        
            | Input power supply | 
            Single phase AC 100 V ± 10% 50/60 Hz | 
        
        
            | Dimension / mass | 
            W430 × H196 × D405 (rack mount, except for protrusions) Approximately 38 kg | 
        
        
            |  Test specification | 
        
        
            | frequency | 
            50/60 Hz (switching) | 
        
        
            | Waveform | 
            Sinusoidal distortion factor 1.0% or less | 
        
        
            | Output voltage | 
            AC 0 ~ 2.50 kV (Note 1)  
            Digital setting with one end grounded panel operation (0.01 kV step). Variable during testing. | 
        
        
            | Blocking current setting | 
            0.1 mA to 200 mA (Note 1) | 
        
        
        
        
            | Output Capacity | 
            500VA | 
        
        
            | Timer setting | 
             
            Ramp-up time: off, 0.1 to 99.9 sec (0.1 sec step), 100 to 200 sec (1 sec step)  
            ramp-down time (1 sec. Step) Test time: off, 0.5 to 99.9 sec (0.1 sec step), 100 to 999 sec : OFF, 0.1 to 99.9 sec (0.1 sec step), 100 to 200 sec (1 sec step) | 
        
        
            | Test judgment method | 
            Window · Comparator method  
            UPPER-FAIL judgment (when the measured current value exceeds the set upper limit value) and  
            LOWER-FAIL judgment (when the measured current value is less than the set lower limit value) | 
        
        
            | voltmeter | 
            Digital AC 0.0 to 2.50 kV (± 1.5% fs) | 
        
        
            | ammeter | 
            Digital 0.01 mA to 200 mA (± 3% fs ± 20 μA) 
             | 
        
        
            | Current measurement resolution | 
            0.01 mA (2 mA / 8.0 mA range)  
            0.1  
            mA (32 mA range) 1 mA (200 mA range) 
             | 
        
        
            |  Function · Interface | 
        
        
            | Memory function | 
            Up to 10 types of test voltage and judgment value can be registered | 
        
        
            | Hold function | 
            It holds (displays) the measured value at the end of the test | 
        
        
            | External control | 
            External I / O, RS-232C, status out (patrol lighting I / F) | 
        
    
Note 1 Since 
the output capacity of this fabrication example is 500 VA, it can also correspond to voltages and currents such as 1000 V / 500 mA, 5000 V / 100 mA.